Logtag Software

Organisations can use this program to quickly and efficiently bulk convert data so they can be transferred to other programs, without the need to open files individually. Data Loggers Browse by Measurement. To customize how the time information is displayed, the following elements may be used. There are two discrete methods available to start a LogTag recording, which are selected during configuration. For use with and wired or wireless LogMaster data loggers.

Each of these menu groups is explained in more depth in the subsequent sections. It validates coolers and containers that transport temperature-sensitive blood products.

Technology must remain patched and operated in accordance with Federal and Department security policies and guidelines in order to mitigate known and future security vulnerabilities. Overlay multiple logs for mapping applications.

This asks you to make sure you have not neglected to place the LogTag firmly in the Interface Cradle. The logger will be permanently upgraded as soon as the configuration is downloaded. The software will only display the menu groups and commands within each menu group that are appropriate depending on what you are currently doing with the software. The LogTag Analyzer Software generates graphs, individual time and temperature readings, customized documents, and gives facilities the ability to print out validation data to support their records. This could be due to internet connectivity issues, due to an incorrect port number or due to a mis-spelt name.

Data Logger Manuals & More

Once your checklist is created, it can be saved, emailed to other users, and loaded onto any handheld device. The usage decision for a component is found in the Decision and Decision Constraints. By default, all statistics are displayed on the Summary tab. All charts that are currently open will be displayed together. This area is provided specifically for LogTag users and contains information for installation and safe operation of LogTag products.

Click record the configuration data and you will see the final confirmation screen. Supports automatic emailing of files for sharing. Section compliance may be reviewed by the Section Office and appropriate remedial action required if necessary. Those readings which are no longer displayed are still present in the file.

Test Cabinets for Environmental Research. If the LogTag is currently recording while you retrieve the information, it will continue to record without interruption. For example, some products may experience freezer burn if they experience an extremely cold condition or experience a colder than ideal temperature for long enough period of time. Shows you how to factor in the barometric pressure and altitude. If there are multiple windows of readings open and being displayed, all of these windows will therefore be automatically closed and only the most recently retrieved set of readings will be displayed.

Report Example Example Report Screen is shown below. Automatic download of data when a new LogTag is inserted into an interface.

For ultimate data convenience, you setup your own dashboard view. Download and Save file before installing. Type Name Source Description There are no references identified for this entry. Once a LogTag has been through the configuration process to get it ready for next use, any readings previously recorded will no longer be available for retrieval.

Reference thermometer software for use in calibration labs or repair shops needing high performance. Basic Smtp And E-mail Settings It is therefore of the utmost importance that you as the sender obtain permission from the recipients to send these files.

LogTag Data Loggers - Support

The following sections will provide an explanation of each of these options so that users will be able to make the best use of the software. The period of time this technology is currently being evaluated, reviewed, and tested in controlled environments.

Name Description No components have been identified for this entry. When an alarm is triggered, the alarm should be cleared and reset as soon as possible.

Florida SHOTS

These statistics are shown on the corresponding Summary tab and are also calculated for each sequence of data points between the inspection marks. We use cookies on this website to improve your shopping experience. Toolbar commands Each picture on the toolbar represents a unique command. LogTag Analyzer allows a number of selected configuration data to be stored in a text file.

Monarch Track-It Software. LogTag download page for additional software and drivers. Instead, you should be using the automated update function, which ensures you only use the version with the same character set as the one already installed. Add a trend graph in real-time, table view of recorded readings, statistical analysis in real- time, current reading display, finding objects games summary data view and more.

View the data that you want to see the way you want to see it. Sends email or text alerts when alarm conditions met. If readings stay inside the range specified by X and Y the alert indicator will not activate. We would be happy to provide expert advice - free of charge and without obligation!

Home en datalogger-monitoring-systems logtag-support. Communication Ports Configuration Time All reading times are displayed in the time zone of the computer Zone used for configuring the LogTag. Free LogTag Analyzer standard software for configuring any LogTag recorder product before deployment and for data analysis and processing once temperature and humidity data are retrieved.

ThermoWorks

Click the right mouse button at the location where you want to add the annotation. Learn More Add to Compare. Use of this technology is strictly controlled and not available for use within the general population.

Applications - LogTag Recorders

This chapter briefly covers some points of interest for computer network administrators. Displays and prints log graphs. The file name for this file can be selected freely by the Network Administrator. The window slider shows there are still readings earlier and later than the displayed data.

You can also view Min, Max and Average Charts and select other options. All start times are aligned. Chart In default configuration, LogTag Analyzer will display downloaded or file opened data as a chart. Choose from the different category headers to find out more and change your default settings.